Device name |
Description |
Product Area |
Product Type |
Channels/Input channels input |
Channels/Output channels output |
Supported algorithms |
Package |
Package dimension/Package dimension length typ. |
Package dimension/Package dimension width typ. |
Package dimension/Package dimension height typ. |
Supply voltage max. |
Interface/Input interface input |
Interface/Output interface output |
Operating ambient temperature min. |
SNR typ. |
Operating ambient temperature max. |
ams AS7057 Medical and Health Sensor - Analog Frontend
|
<div>The AS7057 Biosignal Sensor Analog Frontend (AFE) is the next generation Vital Sign Sensor. It enables the user to detect biosignals such as photoplethysmogram (PPG) and pulse transit time (PTT), as well as proximity. PPG is the most used HRM method. It measures the pulse rate - by sampling light modulated by the blood vessels, which expand and contract as blood pulses through them. Apart from HRM/HRV, optical Blood Pressure and SpO2 are also enabled by the two independent working photodiode inputs of the AS7057. The AS7057 is a size and performance optimized analog frontend to support space-limited applications such as in-ear vital sign monitoring.</div><div>The AS7057 provides three LED driver outputs, samples up to three photodiode inputs, and supports proximity detection integrated into one of the PPG signal channels. This enables high flexibility for several LED and photodiode arrangements in different applications. Furthermore, the AS7057 Biosignal Sensor Analog Frontend provides two ADC channels for simultaneous PPG measurements and an automatic photodiode offset control.</div><div>The AS7057’s low-power design and small form factor are particularly well-suited for application in earbuds, fitness bands, smartwatches, sports watches, and smart patches. In these cases, board space is limited, and users look for extended, multi-day intervals between battery recharges. A thin package dimension makes the AS7057 suitable for height-constrained solutions like earbuds.</div>
|
Sensor solutions
|
Analog Frontend
|
3 detector
|
3
|
Heart rate
Heart rate variability
SpO2
|
WLCSP
|
1.68 mm
|
1.68 mm
|
0.4 mm
|
1.98 V
|
I²C slave
|
I²C slave
|
-30 °C
|
107 dB
|
85 °C
|
ams AS7058 High Performance Vital Sign - Analog Frontend
|
The AS7058 is an integrated multi-vital sign monitoring device, which provides a complete photoplethysmogram (PPG), electrocardiogram (ECG), body impedance (BioZ), and electrodermal activity (EDA). PPG measures the pulse rate or blood oxygen by sampling light modulated by the blood vessels, which expand and contract as blood pulses through them. ECG is the reference for any measurement of the biopotential generated by the heart. With EDA, it is possible to measure the skin’s water content, and with BioZ, the body composition with an electrical system.
|
Sensor solutions
|
Analog Frontend
|
8 detector
|
8
|
Heart rate
Heart rate variability
Blood pressure
SpO2
|
WLCSP
|
2.82 mm
|
2.55 mm
|
0.4 mm
|
1.98 V
|
I²C slave
SPI (16MHz)
|
I²C slave
SPI (16MHz)
|
-30 °C
|
120 dB
|
85 °C
|
ams AS7050 Medical and Health Sensor - Analog Frontend
|
<div>The AS7050 Biosignal Sensor Analog Frontend is the next generation Vital Sign Sensor. It enables the user to detect biosignals such as photoplethysmogram (PPG), electrocardiogram (ECG) and galvanic skin resistance (GSR). PPG is the most used HRM method. It measures the pulse rate by sampling light modulated by the blood vessels, which expand and contract as blood pulses through them. ECG is the reference for any measurement of the biopotential generated by the heart. </div><div>Compared to the previous ams-OSRAM biosignal sensor generation, AS7050 is a biosignal converting unit. The AS7050 provides up to 8 LED driver outputs, samples up to 6 photodiode inputs and supports external electrodes. This enables the highest flexibility for several LED and photodiode arrangements in different applications. Furthermore, the AS7050 Biosignal Sensor Analog Frontend provides 2 ADC channels for simultaneous PPG and ECG measurements and an automatic photodiode offset control. <span style="color: inherit; font-family: inherit; font-weight: 300;">The embedded ECG analog front-end satisfies IEC 60601-2-47 requirements.</span></div><div>The AS7050’s low-power design and small form factor are particularly well suited to application in fitness bands, smartwatches, sports watches, smart patches and earbuds. In these cases, board space is limited, and users look for extended, multi-day intervals between battery recharges. Thin package dimension makes the AS7050 suitable for height constrained solution likes earbuds.</div>
|
Sensor solutions
|
Analog Frontend
|
6 detector
|
8
|
Heart rate
Heart rate variability
SpO2
Blood pressure
|
WLCSP
|
2.56 mm
|
2.56 mm
|
0.4 mm
|
1.98 V
|
I²C
SPI (16MHz)
|
I²C slave
SPI (16MHz)
|
-30 °C
|
85 °C
|
ams AS7056 Medical and Health Sensor - Analog Frontend
|
<div>The AS7056 Biosignal Sensor Analog Frontend (AFE) is the next generation Vital Sign Sensor. It enables the user to detect biosignals such as photoplethysmogram (PPG) and pulse transit time (PTT), as well as proximity. PPG is the most used HRM method. It measures the pulse rate - by sampling light modulated by the blood vessels, which expand and contract as blood pulses through them. Apart from HRM/HRV, optical Blood Pressure and SpO2 are also enabled by the two independent working photodiode inputs of the AS7056. The AS7056 is a size and performances optimized analog frontend to support space-limited applications such as in-ear vital sign monitoring.</div><div>The AS7056 provides two LEDs and one VCSEL driver outputs, samples up to three photodiode inputs, and supports proximity detection integrated into one of the PPG signal channels. This enables high flexibility for several LED and photodiode arrangements in different applications. Furthermore, the AS7056 Biosignal Sensor Analog Frontend provides two ADC channels for simultaneous PPG measurements and an automatic photodiode offset control.</div><div>The AS7056’s low-power design and small form factor are particularly well-suited for application in earbuds, fitness bands, smartwatches, sports watches, and smart patches. In these cases, board space is limited, and users look for extended, multi-day intervals between battery recharges. A thin package dimension makes the AS7056 suitable for height-constrained solutions like earbuds.</div>
|
Sensor solutions
|
Analog Frontend
|
3 detector
|
3
|
Heart rate
Heart rate variability
SpO2
|
WLCSP
|
1.68 mm
|
1.68 mm
|
0.4 mm
|
1.98 V
|
I²C slave
|
I²C slave
|
-30 °C
|
107 dB
|
85 °C
|