OSRAM DURIS® E 2835, GW JTLPS1.EM

×

Beschreibung

The pre-molded 2835 LED version with standard 2835 footprint provides competitive value in application and system level. The DURIS® E 2835 combines high efficacy and a wide beam angle into a compact format (2.8 mm x 3.5 mm). This is key to homogeneous illumination applications where the DURIS® E 2835 never fails to impress with its performance on system level.

Details

Parameter

Color of emission
White
CRI
80
Electrical power
0.44 W
Mid
Brightness
ΦV
76 lm
IV
25.2 cd
ΦE
230 mW
IE
76.1 mW/sr
Beam angle
120 °
Operating temperature
Top min.
-40 °C
Top max.
100 °C
Dimension
l
3.5 mm
w
2.8 mm
h
0.7 mm

Bestellnummern

Produkt-Typ Beschreibung Bestellnummer Verfügbarkeit
GW JTLPS1.EM-JNKN-XX510-1-G2 ΦV = 60 ... 80 lm, Mountingmethode:SDCM 5, 2200 K (IF = 150 mA) Q65113A7250
GW JTLPS1.EM-LKLL-XX35-1-G2 ΦV = 80 ... 88 lm, Mountingmethode:SDCM 3, 4000 K (IF = 150 mA) Q65113A9162
GW JTLPS1.EM-LKLN-XX53-1-G2 ΦV = 80 ... 96 lm, Mountingmethode:SDCM 5, 5000 K (IF = 150 mA) Q65112A9123
GW JTLPS1.EM-LKLN-XX52-1-G2 ΦV = 80 ... 96 lm, Mountingmethode:SDCM 5, 5700 K (IF = 150 mA) Q65112A9122
GW JTLPS1.EM-LKMK-XX55-1-G2 ΦV = 80 ... 100 lm, Mountingmethode:SDCM 5, 4000 K (IF = 150 mA) Q65113A7950
GW JTLPS1.EM-LKLN-XX51-1-G2 ΦV = 76 ... 96 lm, Mountingmethode:SDCM 5, 6500 K (IF = 150 mA) Q65113A7254
GW JTLPS1.EM-KMKN-XX37-1-G2 ΦV = 72 ... 80 lm, Mountingmethode:SDCM 3, 3000 K (IF = 150 mA) Q65113A9163
GW JTLPS1.EM-KMKN-XX38-1-G2 ΦV = 72 ... 80 lm, Mountingmethode:SDCM 3, 2700 K (IF = 150 mA) Q65113A9175
GW JTLPS1.EM-LKLL-XX31-1-G2 ΦV = 80 ... 88 lm, Mountingmethode:SDCM 3, 6500 K (IF = 150 mA) Q65113A9170
GW JTLPS1.EM-JNKK-XX310-1-G2 ΦV = 60 ... 68 lm, Mountingmethode:SDCM 3, 2200 K (IF = 150 mA) Q65113A9174
GW JTLPS1.EM-LKLL-XX33-1-G2 ΦV = 80 ... 88 lm, Mountingmethode:SDCM 3, 5000 K (IF = 150 mA) Q65113A9161
GW JTLPS1.EM-KNLM-XX56-1-G2 ΦV = 72 ... 92 lm, Mountingmethode:SDCM 5, 3500 K (IF = 150 mA) Q65113A7252
GW JTLPS1.EM-KNLK-XX36-1-G2 ΦV = 76 ... 84 lm, Mountingmethode:SDCM 3, 3500 K (IF = 150 mA) Q65113A9166
GW JTLPS1.EM-KMLM-XX58-1-G2 ΦV = 68 ... 92 lm, Mountingmethode:SDCM 5, 2700 K (IF = 150 mA) Q65113A7251
GW JTLPS1.EM-LKLL-XX32-1-G2 ΦV = 80 ... 88 lm, Mountingmethode:SDCM 3, 5700 K (IF = 150 mA) Q65113A9165
GW JTLPS1.EM-KMLM-XX57-1-G2 ΦV = 72 ... 92 lm, Mountingmethode:SDCM 5, 3000 K (IF = 150 mA) Q65113A7253
GW JTLPS1.EM-JMKM-XX510-1 ΦV = 56.0 ... 76.0 lm, Mountingmethode:SDCM 5, 2200 K (IF = 150 mA) Q65113A7310
GW JTLPS1.EM-KLKN-XX36-1 ΦV = 68.0 ... 80.0 lm, Mountingmethode:SDCM 3, 3500 K (IF = 150 mA) Q65113A9154
GW JTLPS1.EM-KLLL-XX56-1 ΦV = 68.0 ... 88.0 lm, Mountingmethode:SDCM 5, 3500 K (IF = 150 mA) Q65113A2652
GW JTLPS1.EM-KLKN-XX32-1 ΦV = 68.0 ... 80.0 lm, Mountingmethode:SDCM 3, 5700 K (IF = 150 mA) Q65113A9157
GW JTLPS1.EM-KMLM-XX53-1 ΦV = 72.0 ... 92.0 lm, Mountingmethode:SDCM 5, 5000 K (IF = 150 mA) Q65113A7320
GW JTLPS1.EM-KMLK-XX35-1 ΦV = 72.0 ... 84.0 lm, Mountingmethode:SDCM 3, 4000 K (IF = 150 mA) Q65113A9155
GW JTLPS1.EM-JNKN-XX58-1 ΦV = 60.0 ... 80.0 lm, Mountingmethode:SDCM 5, 2700 K (IF = 150 mA) Q65113A7309
GW JTLPS1.EM-KMLL-XX55-1 ΦV = 72.0 ... 88.0 lm, Mountingmethode:SDCM 5, 4000 K (IF = 150 mA) Q65113A4403
GW JTLPS1.EM-KLLL-XX52-1 ΦV = 68.0 ... 88.0 lm, Mountingmethode:SDCM 5, 5700 K (IF = 150 mA) Q65113A2655
GW JTLPS1.EM-JNKL-XX38-1 ΦV = 60.0 ... 72.0 lm, Mountingmethode:SDCM 3, 2700 K (IF = 150 mA) Q65113A9167
GW JTLPS1.EM-KKLK-XX57-1 ΦV = 64.0 ... 84.0 lm, Mountingmethode:SDCM 5, 3000 K (IF = 150 mA) Q65113A7311
GW JTLPS1.EM-JMKK-XX310-1 ΦV = 56.0 ... 68.0 lm, Mountingmethode:SDCM 3, 2200 K (IF = 150 mA) Q65113A9181
GW JTLPS1.EM-KLKN-XX31-1 ΦV = 68.0 ... 80.0 lm, Mountingmethode:SDCM 3, 6500 K (IF = 150 mA) Q65113A9158
GW JTLPS1.EM-KKKM-XX37-1 ΦV = 64.0 ... 76.0 lm, Mountingmethode:SDCM 3, 3000 K (IF = 150 mA) Q65113A9153
GW JTLPS1.EM-KLLL-XX51-1 ΦV = 68.0 ... 88.0 lm, Mountingmethode:SDCM 5, 6500 K (IF = 150 mA) Q65113A2656
GW JTLPS1.EM-KMLK-XX33-1 ΦV = 72.0 ... 84.0 lm, Mountingmethode:SDCM 3, 5000 K (IF = 150 mA) Q65113A9156

Downloads

Datenblätter

Datasheet
Datasheet

Anwendungshinweise

Tools

Horticulture