ams AS7050 Medical and Health Sensor - Analog Frontend

Not for new design
×
Not for new design

설명

The AS7050 Biosignal Sensor Analog Frontend is the next generation Vital Sign Sensor. It enables the user to detect biosignals such as photoplethysmogram (PPG), electrocardiogram (ECG) and galvanic skin resistance (GSR). PPG is the most used HRM method. It measures the pulse rate by sampling light modulated by the blood vessels, which expand and contract as blood pulses through them. ECG is the reference for any measurement of the biopotential generated by the heart. 
Compared to the previous ams-OSRAM biosignal sensor generation, AS7050 is a biosignal converting unit. The AS7050 provides up to 8 LED driver outputs, samples up to 6 photodiode inputs and supports external electrodes. This enables the highest flexibility for several LED and photodiode arrangements in different applications. Furthermore, the AS7050 Biosignal Sensor Analog Frontend provides 2 ADC channels for simultaneous PPG and ECG measurements and an automatic photodiode offset control. The embedded ECG analog front-end satisfies IEC 60601-2-47 requirements.
The AS7050’s low-power design and small form factor are particularly well suited to application in fitness bands, smartwatches, sports watches, smart patches and earbuds. In these cases, board space is limited, and users look for extended, multi-day intervals between battery recharges. Thin package dimension makes the AS7050 suitable for height constrained solution likes earbuds.

세부 정보

조건

Channels
input
6
output
8
Supported algorithms
Heart rate
Heart rate variability
SpO2
Blood pressure
Package
WLCSP
Package dimension
l
2.56 mm
w
2.56 mm
h
0.4 mm
Supply voltage
max.
1.98 V
Interface
input
I²C
SPI (16MHz)
output
I²C slave
SPI (16MHz)
Operating ambient temperature
min.
-30 °C
max.
85 °C

주문 정보

제품 유형 설명 주문 코드 재고 여부
AS7050-BWLM_REV.C Q65114A1288 새로운 설계 계획 없음
AS7050-BWLT Q65114A1287 새로운 설계 계획 없음
AS7050A-BWLT WLP LF T&R With ams OSRAM Algorithm Q65114A2894 새로운 설계 계획 없음

다운로드

데이터시트

AS7050 DS001051 · Short datasheet · PDF · en_US

애플리케이션 노트

AS7050 SpO2 Calibration Note AN001044 · Product related · PDF · en_US

기술 문서

AS705x FS001011 1-00 · Factsheet · PDF · en_US
AS7050_PD001036_1-00 · Technical note · PDF · en_US

이미지

AS705x Top with brand · Images · JPG
AS7050_BD001019_1-00 · Block diagram · JPG

소프트웨어

AS7050_Demo_v1-0-0.zip · Demo · ZIP · en_US
AS7050_EvalSW_pWin_v2.0.0.0.zip · Evaluation software · ZIP · en_US
AS7050_EvalSW_lin_v2.0.0.0.zip · Evaluation software · ZIP · en_US
AS7050_EvalSW_osx_v2.0.0.0.zip · Evaluation software · ZIP · en_US
AS7050_Lib_intlib_v1-0-0.zip · Library · ZIP · en_US