OSRAM OSCONIQ™ P 2226, GW DASPA2.EC

×

Beschreibung

High-efficacy mid-power LED with long lifetimes also at high currents and high junction temperatures.

Details

Parameter

Color of emission
White
CRI
80
Electrical power
0.29 W
Mid
Brightness
ΦV
37 lm
IV
10.1 cd
ΦE
114 mW
IE
31.2 mW/sr
Beam angle
130 °
Operating temperature
Top min.
-40 °C
Top max.
120 °C
Dimension
l
2.6 mm
w
2.2 mm
h
1.3 mm

Bestellinformation

Produkt-Typ Beschreibung Bestellnummer Verfügbarkeit
GW DASPA2.EC-HRHT-5U8X-1 ΦV = 33 ... 42 lm, 2700 K (IF = 100 mA) Q65112A5408 volle Produktion
GW DASPA2.EC-HSHU-5O8Q-1 ΦV = 36 ... 45 lm, 3500 K (IF = 100 mA) Q65112A5410 volle Produktion
GW DASPA2.EC-HSHU-5R8T-1 ΦV = 36 ... 45 lm, 3000 K (IF = 100 mA) Q65112A5409 volle Produktion
GW DASPA2.EC-HTJP-5C7E-1 ΦV = 39 ... 48 lm, 6500 K (IF = 100 mA) Q65112A5415 volle Produktion
GW DASPA2.EC-HTJP-5F7G-1 ΦV = 39 ... 48 lm, 5700 K (IF = 100 mA) Q65112A5414 volle Produktion
GW DASPA2.EC-HTJP-5H7I-1 ΦV = 39 ... 48 lm, 5000 K (IF = 100 mA) Q65112A5413 volle Produktion
GW DASPA2.EC-HTJP-5J7K-1 ΦV = 39 ... 48 lm, 4500 K (IF = 100 mA) Q65112A5412 volle Produktion
GW DASPA2.EC-HTJP-5L7N-1 ΦV = 39 ... 48 lm, 4000 K (IF = 100 mA) Q65112A5411 volle Produktion

Downloads

Datenblätter

GW DASPA2.EC · Datasheet · PDF · en_US

Anwendungshinweise

Brilliant Mix and Mix-to-Match — Professional white for general lighting applications · Product related · PDF · en_US
Light quality — White light parameters · Product related · PDF · en_US
Light quality — Color metrics · Product related · PDF · en_US
Customer complaint management — Details on return shipments for failure analysis request (FAR) · General information · PDF · en_US
Details on photobiological safety of LED light sources · General information · PDF · en_US
Importing rayfiles and ray-measurement files of LEDs · General information · PDF · en_US
Chemical compatibility of LEDs · General information · PDF · en_US
欧司朗光电半导体有限公司 LED 的测量、 · General information · PDF · en_US
ESD protection while handling LEDs · Handling recommendations · PDF · en_US
Dry pack information · Handling recommendations · PDF · en_US
Weitere Hinweise zum bleifrei Reflow-Löten von LEDs · Soldering and processing · PDF · en_US
Manual lead-free soldering of LEDs · Soldering and processing · PDF · en_US
Comparison of simple LED circuits for low power LEDs · Electrical design · PDF · en_US
Determination of resistances for brightness compensation · Electrical design · PDF · en_US
Dimming InGaN LEDs · Electrical design · PDF · en_US
LED driving technology for long term flexibility · Electrical design · PDF · en_US
The basic principles of Electrical Overstress (EOS) · Electrical design · PDF · en_US

Ressourcen

CAD Data · CAD Data · FOLDER
Electrical Simulation · Electrical Simulation · FOLDER
Optical Simulation · Optical Simulation · FOLDER

Bilder

DURIS P 5 GW DASPA1.EC · Images · TIF

Tools

LightGuide

Calculate the effectiveness of an LED based on a selected light guide by showing the amount of incoupled, reflected and missed light rays.